Q1. Minimum plinth height recommended as per IS code is
- 300 mm
B. 400 mm
C. 450 mm β
D. 600 mm
Explanation: Prevents dampness and flood water entry.
Q2. Carpet area of a building includes
- Wall thickness
B. Balcony area
C. Usable living area only β
D. Staircase
Q3. The strongest bond in brick masonry is
- Flemish bond
B. Header bond
C. English bond β
D. Stretcher bond
Q4. Which foundation is best suited for low bearing capacity soil?
- Isolated footing
B. Strip footing
C. Raft foundation β
D. Grillage foundation
Q5. Standard size of brick as per IS code is
- 230 Γ 110 Γ 75 mm
B. 190 Γ 90 Γ 90 mm β
C. 200 Γ 100 Γ 100 mm
D. 180 Γ 85 Γ 85 mm
Q6. Purpose of bond in masonry is to
- Improve appearance
B. Reduce cost
C. Distribute load uniformly β
D. Increase speed
Q7. Which door is most suitable for hospitals?
- Panelled door
B. Flush door
C. Sliding door β
D. Battened door
Q8. Minimum headroom in a staircase should be
- 1.8 m
B. 2.0 m
C. 2.1 m β
D. 2.4 m
Q9. Relationship between riser (R) and tread (T) is
- R + T = 450
B. R = T
C. 2R + T = 600β650 mm β
D. R/T = 2
Q10. Which roof is preferred in heavy rainfall areas?
- Flat roof
B. RCC roof
C. Pitched roof β
D. Shell roof
Q11. Efflorescence in masonry is caused due to
- Excess cement
B. Moisture movement
C. Soluble salts β
D. Poor workmanship
Q12. Minimum width of stair in residential buildings
- 600 mm
B. 750 mm
C. 900 mm β
D. 1200 mm
Q13. Window sill height is generally
- 300 mm
B. 450 mm
C. 750β900 mm β
D. 1200 mm
Q14. Which paint is best for exterior walls?
- Distemper
B. Oil paint
C. Enamel paint
D. Cement paint β
Q15. Which foundation uses pile cap?
- Raft foundation
B. Strip footing
C. Pile foundation β
D. Combined footing
Q16. Standard thickness of partition wall is
- 75 mm
B. 100 mm β
C. 150 mm
D. 230 mm
Q17. Which defect appears as white powder on wall surface?
- Cracking
B. Dampness
C. Efflorescence β
D. Peeling
Q18. Which staircase occupies least floor area?
- Dog-legged stair
B. Open well stair
C. Spiral stair β
D. Straight stair
Q19. DPC is generally provided at
- Roof level
B. Window sill level
C. Plinth level β
D. Foundation base
Q20. Which bond is most decorative?
- English bond
B. Flemish bond β
C. Header bond
D. Stretcher bond
Q21. Standard height of residential room is
- 2.4 m
B. 2.6 m
C. 2.75 m β
D. 3.0 m
Q22. Which is NOT a function of foundation?
- Load transfer
B. Stability
C. Decoration β
D. Settlement control
Q23. Best method to prevent dampness
- Painting
B. Whitewashing
C. Damp proof course (DPC) β
D. Plastering
Q24. Roof suitable for large column-free halls
- Flat roof
B. Pitched roof
C. Shell roof β
D. Timber roof
Q25. English bond consists of
- Only headers
B. Only stretchers
C. Alternate header & stretcher courses β
D. Random arrangement
π‘ NUMERICAL MCQs (26β50)
Q26. FAR if plot area = 200 mΒ² and total floor area = 300 mΒ²
- 1.25
B. 1.5 β
C. 2.0
D. 0.75
Q27. Number of bricks required for 2 mΒ³ masonry
- 500
B. 750
C. 1000 β
D. 1500
(500 bricks per mΒ³)
Q28. Load on column = 600 kN, SBC = 200 kN/mΒ². Area of footing
- 2 mΒ²
B. 3 mΒ² β
C. 4 mΒ²
D. 5 mΒ²
Q29. Height of stair = 3 m, riser = 150 mm. Number of steps
- 15
B. 18
C. 20 β
D. 22
Q30. Volume of plaster for 100 mΒ² wall with 12 mm thickness
- 1.0 mΒ³
B. 1.2 mΒ³ β
C. 1.5 mΒ³
D. 2.0 mΒ³
Q31. Window area required for 20 mΒ² room (10%)
- 1.0 mΒ²
B. 2.0 mΒ² β
C. 2.5 mΒ²
D. 3.0 mΒ²
Q32. Area of footing for load 800 kN, SBC 160 kN/mΒ²
- 4
B. 5 β
C. 6
D. 8
Q33. Number of bricks in 1.5 mΒ³ masonry
- 500
B. 750 β
C. 1000
D. 1200
Q34. If riser = 150 mm, suitable tread is
- 200 mm
B. 300 mm β
C. 350 mm
D. 400 mm
Q35. Thickness of RCC slab generally adopted
- 75 mm
B. 100 mm β
C. 150 mm
D. 200 mm
Q36. Height of parapet wall is usually
- 600 mm
B. 750 mm
C. 900 mm
D. 1000 mm β
Q37. Stair slope generally lies between
- 10Β°β20Β°
B. 20Β°β25Β°
C. 25Β°β40Β° β
D. 45Β°β60Β°
Q38. Cement bags required for 1 mΒ³ of 1:6 mortar
- 3
B. 4
C. 5 β
D. 7
Q39. Height of one storey residential building
- 2.5 m
B. 3.0 m β
C. 3.5 m
D. 4.0 m
Q40. Width of standard residential door
- 0.75 m
B. 0.9 m β
C. 1.0 m
D. 1.2 m
Q41. Thickness of DPC usually provided
- 15 mm
B. 25 mm β
C. 40 mm
D. 50 mm
Q42. If plot area = 150 mΒ² and FAR = 1.5, total floor area
- 200 mΒ²
B. 225 mΒ² β
C. 250 mΒ²
D. 300 mΒ²
Q43. Standard number of bricks per mΒ³
- 450
B. 500 β
C. 550
D. 600
Q44. Height of window generally
- 0.9 m
B. 1.0 m
C. 1.2 m β
D. 1.5 m
Q45. Minimum width of landing should be
- Half stair width
B. Equal to stair width β
C. Double stair width
D. Fixed 1 m
Q46. RCC lintel depth generally
- 75 mm
B. 150 mm β
C. 200 mm
D. 300 mm
Q47. Plinth area rate includes
- Only wall cost
B. Entire building cost except services β
C. Only foundation
D. Only superstructure
Q48. Stair with no landing is
- Dog-legged
B. Open well
C. Straight stair β
D. Spiral stair
Q49. Thickness of load-bearing wall
- 100 mm
B. 150 mm
C. 230 mm β
D. 300 mm
Q50. Most economical roof for residential building
- Shell roof
B. RCC flat roof β
C. Timber roof
D. Steel roof